DETERMINATION OF LEAD CONTENT IN PAINTS USING FLAME ATOMIC ABSORPTION SPECTROSCOPY

  • Nguyễn Thị Thu Phương
  • Trần Quang Hải
  • Nguyễn Mạnh Hà
  • Nguyễn Thị Thoa
  • Đào Thu Hà
  • Ngô Thúy Vân
  • Cao Văn Hiếu
  • Nguyễn Hoàng Yến
Keywords: Lead, paint, F-AAS.

Abstract

The article published the results of the analysis of lead content in paint by
flame atomic absorption spectrophotometry (F-AAS). Results showed that the
method has good repeatability (RSD = 4.74%), low detection limit and
quantitative limits (LOD = 0.2157mg/l, LOQ = 0.718mg/l), linear range from
0 - 20 mg/l with linear calibration curve is y = 0.0211x + 0.0145 (R2 = 0.9961),
the recovery is 98.672%. The method has been applied to the analysis of lead
content in some paint samples on the market for good results.

điểm /   đánh giá
Published
2021-06-18
Section
RESEARCH AND DEVELOPMENT