Theoretical study on the influence of sprayed water temperature and minimum temperature difference to the efficiency of a humidification – dehumidification desalination unit
Abstract
The main content of the paper focuses on the theoretical study of the heat exchange between sprayed water and air in a humidification – dehumidification unit. The gained results [7] have been validated by using Hou data [1] and show that, in order to achieve the maximum GOR, the mass flow rate ratio between sprayed water and air depends on the sprayed water temperature and the minimum temperature difference Dtmin. Particularly, the spayed water temperature should be from 70oC to 75oC when the minimum temperature difference Dtmin= 5oC.
điểm /
đánh giá
Published
2016-12-02
Issue
Section
ARTILES
Copyright belongs to VNU-HCM “Science and Technology Development” Journal. Any copy or reprinting of any form must be permitted by the Journal.